Spray Coatings / Gunning Mixes
Semi-lightweight and lightweight spray coatings can be used as both heat-insulating linings and medium-low temperature working linings for thermal insulation. They feature convenient construction, high adhesion, low rebound rate, and low labor intensity.
Send MessagePhysical and Chemical Indicators (LGP0.8 - LGP1.3)
|
Item |
LGP0.8 |
LGP1.0 |
LGP1.3 |
|
|
Al₂O₃ (%) |
≥ 30 |
≥ 35 |
≥ 40 |
|
|
Bulk Density (g/cm³) at 110℃×24h |
≤ 0.8 |
≤ 1.0 |
≤ 1.3 |
|
|
Cold Crushing Strength (MPa) |
110℃×24h |
≥ 4 |
≥ 5 |
≥ 7 |
|
Cold Crushing Strength (MPa) |
Test Temp × 3h |
≥ 3 (800℃) |
≥ 4 (1000℃) |
≥ 5 (1200℃) |
|
Permanent Linear Change (%) at Test Temp × 3h |
±0.8 (800℃) |
±0.8 (1000℃) |
±0.8 (1200℃) |
|
|
Thermal Conductivity (W/(m·K)) at 350℃±25℃ |
≤ 0.21 |
≤ 0.25 |
≤ 0.35 |
|
|
Max Operating Temperature (℃) |
800 |
1000 |
1200 |
|
Physical and Chemical Indicators
|
Item |
LGP1.5 |
LGP1.8 |
LGP1.8T |
|
|
Al₂O₃ (%) |
≥ 42 |
≥ 45 |
≥ 55 |
|
|
Bulk Density (g/cm³) at 110℃×24h |
≤ 1.5 |
≤ 1.8 |
≤ 1.8 |
|
|
Cold Crushing Strength (MPa) |
100℃×24h |
≥ 12 |
≥ 15 |
≥ 12 |
|
Cold Crushing Strength (MPa) |
Test Temp × 3h |
≥ 10 (1300℃) |
≥ 13 (1300℃) |
≥ 10 (1400℃) |
|
Permanent Linear Change (%) at Test Temp × 3h |
±0.8 (1300℃) |
±0.8 (1300℃) |
±1.0 (1400℃) |
|
|
Thermal Conductivity (W/(m·K)) at 350℃±25℃ |
≤ 0.4 |
≤ 0.7 |
≤ 0.75 |
|
|
Max Operating Temperature (℃) |
1300 |
1300 |
1500 |
|